Temperature and humidity
Compare conditions at selected points in racks and the room. Reading history helps identify changes and assess the effects of cooling adjustments.
Sensors with or without a display
eMonit Cloud IoT
Temperature, humidity, leaks and technical signals. Check your server room online and receive alerts when action is needed.
Choose your monitoring setupFrom one rack to multiple sites
Choose monitoring to suit your infrastructure. Each measurement or event requires an appropriate sensor and configuration.
Compare conditions at selected points in racks and the room. Reading history helps identify changes and assess the effects of cooling adjustments.
Sensors with or without a displayPosition sensors at agreed locations, such as near cooling equipment or under a raised floor. Receive a notification when water is detected.
Leak sensorsMonitor selected power signals or energy consumption. Reading UPS status requires a compatible interface and confirmation that integration is possible.
Technical signals and current transformersA door contact detects when a door or cabinet opens. Motion and presence sensors can complement room monitoring, depending on your needs.
Door contacts, PIR and presence sensorsDo you also need vibration, air quality or another signal? Explore eMonit sensor types. Available features depend on the selected devices.
From reading to response
In eMonit Cloud IoT you can check readings and history from selected sensors, using a browser on a computer, tablet or phone.

Measuring a parameter or detecting an event.
Receiving data and checking the alert rule.
Information for designated recipients.
Selected for your infrastructure
Sensor connections and the site's internet connection are two parts of the installation. We select them together.
For fixed measurement points with available cable routes. The interface, measurement module and power supply are selected for the equipment.
LoRaWAN or Wi-Fi, depending on the model and infrastructure. In server rooms with metal cabinets, we check transmission conditions before deployment.
Data can use the local network or a suitable cellular module. GSM requires coverage and an appropriate data service.
New online readings require working connectivity. Measurement and transmission also require device power. Data buffering, backup power and an alternative connection depend on the project; they are not automatically available in every setup.
If monitoring must operate during an outage, we will include this requirement in equipment selection and testing.
Selection and pricing
One rack, a technical room or several sites? A description of the infrastructure and your expectations is enough. You do not need to choose sensor models yourself.
Ask for advice and a quoteTell us the number of racks or rooms and what you want to measure and detect.
Describe LAN access, cable routing options and requirements during outages.
We will agree on thresholds, recipients and history requirements. At commissioning, we check readings and the agreed notifications.
We select points based on rack layout, airflow and measurement purpose. A reading at one location does not describe the entire room. A floor plan and information about cooling and the areas you want to observe will help.
Thresholds are selected for the equipment and application, taking account of device documentation and the administrator's rules. We do not use one temperature for all server rooms. Alert delays and hysteresis can be configured for measurements.
A dedicated computer is not required just to view the data. A suitable device or gateway sends measurements to the system and needs the required power and connectivity. Open the dashboard in a browser whenever you need access.
We first check models, available interfaces and protocols. Not every sensor or UPS makes data available in a supported format. Send device documentation so we can confirm integration options.
Yes, after checking device compatibility and infrastructure capacity. The system can collect data from multiple sites and share selected sensors with authorised users.
The number of points, sensor types, installation, communication modules and service scope. Outage operation, data history and alert channels also affect the quote. Send a description of the installation so we can select a suitable solution.
Monitoring supports administrator oversight and response. It does not replace backup power, access control or fire protection systems.
We will select the measurement scope and alert delivery method.